Pakistan RO System Project
1.Project Brief
Pakistan petroleum enterprise used reverse osmosis process to treat river water, and reverse osmosis permeate water is deeply treated by back-end process as factory boiler feed water.
2.Technological Process
River water—MMF—UF—Cartrige filter—RO
3.System Quick Facts
| Element Model | Permeate Flux | Recovery | Operating Pressure | Permeate Flow | Pressure Vessel Array |
| BW-8040 | 24.9LMH | 75% | 0.8-1.2MPa | 100m³/h | 12:6 (6 cores) |
4.System Operation Data
| Date | Operating Pressure | Permeate Flow | Recovery | Salt Rejection | Temperature |
| 2020.5 | 9.5bar | 100m³/h | 75.2% | 98.8% | 28℃ |
Replacement & Parts Center
Find a compatible BOKAWATER alternative
Search an installed brand, model, SKU or product type. RO membrane matching is available now; other categories are handled through an engineering review with nameplate or BOM upload.BOKAWATER Solution Hub
Find products, engineering solutions and compatible replacements
Start with the equipment, water challenge or installed component. Each path leads to technical data and a product-specific inquiry.ProductsRO systems, membranes, wastewater equipment and process systems.SolutionsSelect by feed water, industry, treatment target and capacity.Replacement & PartsSearch standard products and request an engineering-confirmed alternative.ProjectsReview treatment applications and delivered system references.Knowledge CenterEngineering answers, comparisons, maintenance and selection guidance.CatalogsProduct data, specifications and downloadable technical material.